REBAR DETAIL OF SLAB
Slabs
SCOPE:
Flat slab
One way / Two way slab
Cantilever slab
Trough (Rip) and Coffered slab
DETAILING STANDARDS:
Nominal Cover to Reinforcement:
Internal :15mm or bar size + ΔCdev (5 or 10mm)
External : 35mm + ΔCdev (5 or 10mm)
Spacing and Size of bars:
Minimum spacing : 75mm (at laps)
Maximum main bar spacing : ≤ 3D or 400mm
Maximum secondary bar spacing : ≤ 3.5D or 450mm
Minimum bar size : 10mm
Bar arrangements:
Top bar if support within stock length,
Top bars if support beyond stock length
Bottom bar if support within stock length,
Slab end reinforcement:
FLAT SLAB
Strip arrangement detail for Top bars
Strip arrangement details of Bottom Bars
1. Openings to be ignored, If size ≤ 150mm.
2. If opening size ≤ 300mm, main bars to be displaced at site either side of opening; no
trimmers required and diagonal bars required for anti-crack.
3. If opening size ≤ 500mm and Ø ≥ 20mm, main bars to be displaced at site either side of
opening; no trimmers required; diagonal bars required for anti-crack and sacrificial bars may
be required to satisfy maximum spacing of bars.
4. If opening size ≤ 500mm and Ø ≤ 16mm, main bars to be cut at site; end u-bars, trimmers
and diagonal bars to be detailed as shown below.
5. If opening size > 500mm, cut the main reinforcement; end u-bars, trimmers and diagonal bars
to be detailed as shown below.
Punching shear details:
Column Drop: